HV 3000

The HV3000 Heat Up Burners have a maximum capacity of 300 Nm³/h of natural gas and 5,800 Nm³/h of combustion air. They feature flame supervision by UV cells. In case of flame failure, the gas supply will be stopped within 2 seconds by safety shutoff solenoid valves.

  • Doubled capacity for larger industrial heat-up applications.
  • Versatile usage across multiple furnace types and refractory linings.
  • Maintains uniform heat zones, reducing risk of cracking or stress.
  • Portable design suitable for field use and plant integration.
  • Compatible with multiple fuel types (gas or oil).
  • Equipped with automated controls for precision heating.
  • High durability even under continuous operation.
  • Proven performance in cement, steel, glass, and non-ferrous industries.

Pos.1 Combustion air fan with Burner Control Unit (BCU) 

Current consumption:

15 kW, direct start

Voltage:

440 V, 3 phases, ground, 63 A

Dimensions:

800 x 1200 mm (LxW), installed on wheels

Sound:

83 dba 

BCU:

UV flame supervision, PLC controlled, alarm

Weight:

280kg 

Pos 2: Gas/Fuel Supply Station

Safety Components:

Double gas safety shutoff, pilot, pressure switch

Burner Cooling/Purging:

Compressed air max 1.5 bar, 5-10 Nm³/h

Max Flow:

300 Nm³/h

Max Pressure:

Inlet 4 bar max, internal pressure reducer to 0.5 bar

Weight:

25 kg

Couplings:

2" Camlock / ¼" Cooling Air

Pos 3: High-Speed Burner, Type HV3000 for Gas

Safety Components:

UV flame sensor, automatic ignition, pressure switch

Power:

300 Nm³/h of natural gas (approximately 3 MW)

Nozzle:

High-temperature steel (1250°C), optional nickel-free

Nozzle Dimensions:

200 x 200 mm (other dimensions on request)

Air Inlet:

250 mm

Gas Inlet:

2" Camlock

Weight:

25 kg

Hotwork International South America S.A.,

Maipú 15, 2900 San Nicolás de los Arroyos Prov.
Buenos Aires,
contact@hotwork.ar+549 336 4466594

Hotwork Group

  • Hotwork Holding AG
  • Hotwork International AG
  • Hotwork International Inc.
  • Hotwork - XiX Ltd
  • MPOT Hotwork Solution Ltd
  • IRSP Ltd
  • Hotwork Heat Treatment & Specialized Services Ltd.
  • Heat Up Latin America S. DE R.L. DE C.V
  • PT Hotwork International Indonesia
  • Heat Applications India Ltd.
  • Heat Applications Global Ltd.
  • Total Project Management Ltd.
  • Hotwork International South America S.A.,
  • Hotwork International Co. Ltd. (Thailand)
Company Logo  Footer

Copyright © 2025 Heat Up Latin America  |

This website uses cookies to ensure you get the best experience on it. By using this website, you agree to the cookies terms.

Read more.Dismiss